Battery Charge Controller

Battery Charge Controller



Design Notes:

Protection Application:
Microprocessor-controlled battery charger adapted for variable input from PV Array. Prevents overcharging of battery. Threats include power line surges, lighting on PV Array Input, improper connections throughout.
Solution Description:
AC Input: Normal Fuse/MOV. SMPS: TVS on DC output. PV Array Input and Batter Charge Output:FKS (164.6185 Series) up to 40 Amps, TOE MAXI (142.6885 Series) up to 80 Amps & TVS.
Companion Solutions:
Jcase Fuse could be used for current from 20A to 60A for voltage up to 50VDC
Regulatory Issues:
Does not apply.
Unique Features:
Does not apply.
Application Warnings:
Does not apply.

Solutions

Solutions