LLC6 Series - Low Level Cutoff Liquid Level Control

Roll Over to Zoom
Disclaimer Notice

Littelfuse products are not designed for, and shall not be used for, any purpose (including, without limitation, automotive, military, aerospace, medical, life-saving, life-sustaining or nuclear facility applications, devices intended for surgical implant into the body, or any other application in which the failure or lack of desired operation of the product may result in personal injury, death, or property damage) other than those expressly set forth in applicable Littelfuse product documentation. Warranties granted by Littelfuse shall be deemed void for products used for any purpose not expressly set forth in applicable Littelfuse documentation. Littelfuse shall not be liable for any claims or damages arising out of products used in applications not expressly intended by Littelfuse as set forth in applicable Littelfuse documentation. The sale and use of Littelfuse products is subject to Littelfuse Terms and Conditions of Sale, unless otherwise agreed by Littelfuse. "Littelfuse" includes Littelfuse, Inc., and all of its affiliate entities.

The LLC6 Series is a plug-in, single-probe conductive liquid level control designed for low liquid level cutoff protection. It offers a factory fixed time delay of 1 - 60s and is available in input voltages of 24, 120, or 230VAC. LED indicator illuminates whenever the LLC6’s 10A, SPDT output relay is energized. Available with automatic/manual reset or a special manual reset with power outage feature, which auto resets the unit when power is restored and the water level is acceptable. 24VAC and 120VAC units are recognized as limit switches under UL353 (230VAC units are UL508) and CSA certified under Standard 14.


See datasheet for operation and reset details.

Access specifications, certifications, check availability and order parts below

Catalog #Input
Voltage (V)
Output
Form
Time Delay RangeTermination TypeMounting MethodDimensionsWeight (lbs/g)Control TypeHumidityInput AC Line Frequency (Hz)Input Tolerance (%)Isolation Voltage (V)Output Load Rating (VA)Output TypeRepeat Accuracy (%)StockSamplesCompare
LLC6210F10M24 VacNon-isolated SPDT10 s fixed11-pin relay typePlug-in socket2.91 H x 2.39 W x 1.78 D in. (73.9 x 60.7 x 45.2 mm)0 KgON/OFF (single level) resistance sensor with built-in time delay to prevent rapid cycling95% non-condensing50 / 60-0.35≥2500 Vrms input to output10 A resistive @ 240 Vac; 1/4 hp @ 125 Vac; 1/2 hp @ 250 VacElectromechanical relay±10%CheckOrder
LLC6410F10M120 VacNon-isolated SPDT10 s fixed11-pin relay typePlug-in socket2.91 H x 2.39 W x 1.78 D in. (73.9 x 60.7 x 45.2 mm)0 KgON/OFF (single level) resistance sensor with built-in time delay to prevent rapid cycling95% non-condensing50 / 60-0.3≥2500 Vrms input to output10 A resistive @ 240 Vac; 1/4 hp @ 125 Vac; 1/2 hp @ 250 VacElectromechanical relay±10%CheckOrder
LLC643F26M120 VacNon-isolated SPDT3 s fixed11-pin relay typePlug-in socket2.91 H x 2.39 W x 1.78 D in. (73.9 x 60.7 x 45.2 mm)0 KgON/OFF (single level) resistance sensor with built-in time delay to prevent rapid cycling95% non-condensing50 / 60-0.3≥2500 Vrms input to output10 A resistive @ 240 Vac; 1/4 hp @ 125 Vac; 1/2 hp @ 250 VacElectromechanical relay±10%CheckOrder
LLC6610F5P
Obsolete: 2020 -11-13
230 VacNon-isolated SPDT10 s fixed11-pin relay typePlug-in socket2.91 H x 2.39 W x 1.78 D in. (73.9 x 60.7 x 45.2 mm)0 KgON/OFF (single level) resistance sensor with built-in time delay to prevent rapid cycling95% non-condensing50 / 60-0.3≥2500 Vrms input to output10 A resistive @ 240 Vac; 1/4 hp @ 125 Vac; 1/2 hp @ 250 VacElectromechanical relay±10%
To request product environmental information, please complete the Product Environmental Information Request Form.