Littelfuse products are not designed for, and shall not be used for, any purpose (including, without limitation, automotive, military, aerospace, medical, life-saving, life-sustaining or nuclear facility applications, devices intended for surgical implant into the body, or any other application in which the failure or lack of desired operation of the product may result in personal injury, death, or property damage) other than those expressly set forth in applicable Littelfuse product documentation. Warranties granted by Littelfuse shall be deemed void for products used for any purpose not expressly set forth in applicable Littelfuse documentation. Littelfuse shall not be liable for any claims or damages arising out of products used in applications not expressly intended by Littelfuse as set forth in applicable Littelfuse documentation. The sale and use of Littelfuse products is subject to Littelfuse Terms and Conditions of Sale, unless otherwise agreed by Littelfuse. "Littelfuse" includes Littelfuse, Inc., and all of its affiliate entities.

The 777-KW/HP-P2 Series has the overload, voltage, phase loss and reversal, voltage and current unbalance, current and power monitoring*, and underload trip based on power in one package. The underpower trip feature is desirable anytime the current vs. load characteristic is non-linear or has little change. In general terms, smaller motors and slow-speed motors have little change in current over the normal load range. Larger motors that are running light loads will also show small current changes over the operating load range. For standalone applications, the units incorporate a 3-digit LED display that is used for programming, providing real-time operational information and displaying diagnostic codes to aid in troubleshooting a fault condition.

Access specifications, certifications, check availability and order parts below

Catalog #Input
Voltage (V)
Output
Form
Termination TypeMounting MethodFull Load Amp Range (A)DimensionsWeight (lbs/g)Overcurrent Trip ClassOvercurrent Trip PointAddressCurrent Accuracy (%)Current Unbalance Trip Point (%)Ground Fault Accuracy (%)Ground Fault Current Trip Point (A)HumidityStockSamplesCompare
777-575-KW/HP-P2500 - 600 VacSPDT - Form CTorque: 7 in-lbsSurface mount (4 - #8 screws) or DIN rail mount2 - 20 (looped conductors required); 20 - 90 (direct); 90 - 800 (external CTs required)3.05 H x 3.85 W x 5.05 D in. (77.5 x 97.8 x 128.3 mm)0 Kg02 - 60; J02 - J60; L00 - L60; or OFF(20 - 100 A) … MULT of 80 - 140% of CT primaryCOM: C00 - C07; RS-485: A01 - A99±3% (<100 A direct)2 - 50% or 999 (disabled)±15%(3 - 20) … MULT or 12 - 40% of primary CT or OFF10 - 95% non-condensing per IEC 68-2-3CheckOrder
777-HVR-KW/HP-P2340 - 480 VacSPDT - Form CTorque: 7 in-lbsSurface mount (4 - #8 screws) or DIN rail mount2 - 20 (looped conductors required); 20 - 90 (direct); 90 - 800 (external CTs required)3.05 H x 3.85 W x 5.05 D in. (77.5 x 97.8 x 128.3 mm)0 Kg02 - 60; J02 - J60; L00 - L60; or OFF(20 - 100 A) … MULT of 80 - 140% of CT primaryCOM: C00 - C07; RS485: A01 - A99±3% (<100 A direct)2 - 50% or 999 (disabled)±15%(3 - 20) … MULT or 12 - 40% of CT primary or OFF10 - 95% non-condensing per IEC 68-2-3CheckOrder
777-KW/HP-P2200 - 480 VacSPDT - Form CTorque: 7 in-lbsSurface mount (4 - #8 screws) or DIN rail mount2 - 20 (looped conductors required); 20 - 90 (direct); 90 - 800 (external CTs required)3.05 H x 3.85 W x 5.05 D in. (77.5 x 97.8 x 128.3 mm)0 Kg02 - 60; J02 - J60; L00 - L60; or OFF(20 - 100 A) … MULT of 80 - 140% of CT primaryCOM: C00 - C07; RS485: A01 - A99±3% (<100 A direct)2 - 50% or 999 (disabled)±15%(3 - 20) … MULT or 12 - 40% of CT primary or OFF10 - 95% non-condensing per IEC 68-2-3CheckOrder
777-LR-KW/HP-P2200 - 480 VacSPDT - Form CTorque: 7 in-lbsSurface mount (4 - #8 screws) or DIN rail mount1 - 2 (looped conductors required); 2.1 - 9.0 (direct); 10 - 800 (external CTs required)3.05 H x 3.85 W x 5.05 D in. (77.5 x 97.8 x 128.3 mm)0 Kg02 - 60; J02 - J60; L00 - L60; or OFF(2 - 10 A) … MULT of 80 - 140% of CT primaryCOM: C00 - C07; RS485: A01 - A99±3% (<100 A direct)2 - 50% or 999 (disabled)±15%(0.3 - 2.0) … MULT or 6 - 40% of CT primary or OFF10 - 95% non-condensing per IEC 68-2-3CheckOrder
777-MLR-KW/HP-P2200 - 480 VacSPDT - Form CTorque: 7 in-lbsSurface mount (4 - #8 screws) or DIN rail mount0.5 - 5 (looped conductors required); 5 - 21 (direct); 40 -740 (external CTs required)3.05 H x 3.85 W x 5.05 D in. (77.5 x 97.8 x 128.3 mm)0 Kg02 - 60; J02 - J60; L00 - L60; or OFF(2 - 10 A) … MULT of 80 - 140% of CT primaryCOM: C00 - C07; RS485: A01 - A99±3% (<100 A direct)2 - 50% or 999 (disabled)±15%(3 - 20) … MULT or 12 - 40% of CT primary or OFF10 - 95% non-condensing per IEC 68-2-3CheckOrder