231-Insider-P Series - Single-Phase Protection for Submersible Pumps

External overview image
Roll Over to Zoom
Disclaimer Notice

Littelfuse products are not designed for, and shall not be used for, any purpose (including, without limitation, automotive, military, aerospace, medical, life-saving, life-sustaining or nuclear facility applications, devices intended for surgical implant into the body, or any other application in which the failure or lack of desired operation of the product may result in personal injury, death, or property damage) other than those expressly set forth in applicable Littelfuse product documentation. Warranties granted by Littelfuse shall be deemed void for products used for any purpose not expressly set forth in applicable Littelfuse documentation. Littelfuse shall not be liable for any claims or damages arising out of products used in applications not expressly intended by Littelfuse as set forth in applicable Littelfuse documentation. The sale and use of Littelfuse products is subject to Littelfuse Terms and Conditions of Sale, unless otherwise agreed by Littelfuse. "Littelfuse" includes Littelfuse, Inc., and all of its affiliate entities.

The Littelfuse 231-Insider-P fits inside 1/3, 1/2, 3/4, and 1 hp, 230V control boxes and are designed to protect single-phase pumps from dry-well, dead-head, jammed impeller, rapid-cycle, overvoltage, and undervoltage conditions.

A calibration adjustment allows the Insider to be calibrated to your specific pumping applications, thereby reducing the possibility of false or nuisance tripping. A unique microcontroller-based voltage and current-sensing circuit constantly monitors the incoming power for fluctuations, overcurrent, and undercurrent. When an abnormality, such as loss of suction is detected, the product deactivates its output relay and directly disconnects the pump motor. The relay then begins its user-selectable restart delay (dry-well recovery) timer. When the timer counts to zero or power is removed and reapplied, the relay reactivates its output relay and turns the pump back on. By leaving the restart delay knob in the reset position, the relay will operate in manual reset mode.

The Insider communicates with a hand-held diagnostics tool called the Informer (sold separately). The Informer displays parameters including calibration points, trip points, run time and last faults. An IR Kit-12 (12” fiber optic kit) is included with each Insider, allowing the Informer to access these parameters even when the Insider is enclosed in a control box. This is valuable for troubleshooting the pump while it is running.

Access specifications, certifications, check availability and order parts below

Catalog #Input
Voltage (V)
Input Load Range (hp)Output
Form
Mounting MethodWeight (lbs/g)Overcurrent Trip ClassInput AC Line Frequency (Hz)Maximum Input PowerOutput Load Rating (VA)Overvoltage Trip Voltage (%)Rapid Cycle Timer (s)Restart Delay RangeTrip Delay RangeUnderload (%)Undervoltage Reset Voltage (%)StockSamplesCompare
231-INSIDER-P230 Vac1/3 - 1SPSTInside a Franklin™; Pente®; or CentriPro™ control box0 Kg125% of calibration point50 / 60 (50 will increase all delay timers by 20%)51 hp @ 240 Vac (17 A max.)265 Vac4 restarts allowed in 60 s periodOver/Under Voltage: 2 s; All other faults: Manual; 2 - 225 mOvercurrent: 5 s; Dry-well: 4 sAdjustable (70 to 90% of calibrated run power)190 VacCheckOrder
23112000029Check
23112500029Check
23113150029Check
23114000029Check
23115000029Check
23116300029Check
23118000029Check
23121000029Check
23121250029Check
23121600029Check
To request product environmental information, please complete the Product Environmental Information Request Form.